Comment by zamadatix
6 hours ago
There are 2 very different main types of "copper" in this context. Each can break down into more specific subcategories but they have a relatively common general behavior with their primary type.
First there is the BASE-T RJ45 stuff, which it sounds like you might have been working with. At 10G or higher speeds this get relatively power hungry and is not really an advantage over fiber unless you are also delivering PoE or are trying to reuse existing cabling.
This type (DAC) is a special type of pre-made cable assembly which eschews much of the advanced signalling/conversion logic. The upside is the power usage is low (often even lower than fiber) and the cost is dirt cheap. The downside is the lengths are much more limited and it's intended to be preterminated SFP-to-SFP (or the like) cable assemblies instead of modular patching/custom built.
There is indeed a latency difference, usually DAC < fiber < BASE-T, but they are all within a few microseconds (not milliseconds) of each other so you really have to be pressed to care about it (to the point you're looking at specialized low latency switches and paying extra to lay things out in a way which minimizes the number of L2 hops rather than the cost).
> it's intended to be preterminated SFP-to-SFP
I wonder why nobody's making field-terminatable DACs for custom lengths. If you've torn one down, they're not exactly complicated inside.
If they existed, would people buy them?
DAC cables use twinax. Properly terminating twinax is not easy. It's not as forgiving as twisted pair going into an RJ45.
DAC cables have a limited length range. It's not like 10GBASE-T where you can run the cable hundreds of feet and then put a connector on exactly where you need it. The cables only work at short distances so it's easy to stock the cable sizes close enough to everyone's needs.
I think the only reason RJ45 termination is an (occasional) thing for short patching is you're also in spec to go 100 meters with it so the tools and materials to do so are already commonly in use.
For passive DACs the range of lengths is so low you can just get away with having 2 or 3 different lengths on hand and never need to worry about it. Active DACs start to be too much to bother with again.
Fiber it's possible, but again really only because you can go kilometers with it rather than because people want to make short patch cables themselves.
Doesn't that reduce to RJ45?
No. It's twin-axial. Think coaxial, but more axial.
Nope. For production, you want to reduce risk and variation. DACs are already available in about 5 sizes up to the max 7m length, why would you terminate any other size in the field?
I did spec a couple of 7m dacs a few months ago to run between two adjacent bays, but normally for more than 2m I'll just drop a SM sfp and run a preterminated fibre cable.
In the field its the armoured fibre on a reel, 100m, 200m, 500m etc, with opticon connectors, or some normal cat5 typically for APs
2 replies →