Performance gains wouldn’t be that large as enterprise SSDs already have internal capacitors to flush pending writes to NAND.
During typical usage the flash controller is constantly journaling LBA to physical addresses in the background, so that the entire logical to physical table isn’t lost when the drive loses power. With a larger capacitor you could potentially remove this background process and instead flush the entire logical to physical table when the drive registers power loss. But as this area makes up ~2% of the total NAND, that’s at absolute best a 2% performance benefit we are potentially missing out on.
You could gain much more by coalescing repeated writes to the same address - database scenarios for example