Comment by jacquesm

8 hours ago

> Yikes, that sounds dangerous.

It is.

> I'd personally prefer e.g. 48V even if that meant some more losses and/or thicker cables.

That's unfortunately not an option. The problem with the 600 to 1000 V domain is that it is able to creep where lower voltage would stay constrained and high enough that it can jump small gaps and start arcing spontaneously. The fact that it is DC makes it more dangerous still. But from an economy and practical engineering perspective it makes perfect sense. Keep in mind that these cars are often built using Lithium-Ion packs (though fortunately we are finally seeing a change here towards safer options, even if they are slightly less dense and more expensive), so the electrocution risks are small compared to the thermal runaway risks.